Features:
- Operating voltage: three-phase 380VAC;
- The system adopts an integrated design and a manual operation mode with one pump and four outlets, making it more convenient to operate;
- Each output point is equipped with a manual reversing valve, allowing for individual control of that output path and more precise control.
- Each output point is equipped with a pressure gauge to monitor the pressure in real time, ensuring greater safety.
- The system is equipped with a silent motor, making it run more quietly;
- The system frame is specially designed with lifting rings, making lifting easier;
| Model | Working voltage | Motor power | Oil capacity | Working pressure | Flow rate | Control mode | Control points | Dimension |
|---|---|---|---|---|---|---|---|---|
| (V) | (KW) | (L) | (bar) | (L/min) | (mm) | |||
| LS-IM-2 | AC380V 50Hz | 3 | 60 | 700 | 0.8 | Manual | 2 | 500*520*700 |
| LS-IM-4 | AC380V 50Hz | 5.5 | 100 | 700 | 0.8 | Manual | 4 | 800*520*780 |
Application Cases
Frequently Asked Questions – Synchronous Jacking System
Our system can reach +/-1mm accuracy.
If customer has high requirements, our variable frequency system can reach +/-0.1mm accuracy.
Usually it’s 4, 8, 12 and 16 jacks.
AC380V 50Hz.
It will be one complete system including hydraulic jacks, control pump station, displacement sensor, pressure sensor, cables, hydraulic hoses etc.
Yes, customers just need leave the requirements, the quantity of systems, our engineers will design the program and connect the several systems together and user just need operate one of them but control all.